Skip to content
Gateway Scientific — your gateway to all of your calibration needs

Accurate. Traceable.
Dependable.

You have the whole lab. We can service it — pipettes, balances, dispensers and the instruments around them — under one provider, one point of contact, one set of records.

  • Pipette calibration
  • Laboratory instrument calibration
  • Calibration programs
  • Professional documentation
  • Competitive pricing
  • Flexible scheduling
  • Responsive service
A laboratory technician performing a gravimetric pipette calibration on an analytical balance

Gravimetric method

ISO 8655-6

Environment-corrected, at your bench.

Calibration recordSingle-channel · 10–100 µL
Pass
VolumeAs-foundAs-left
100.0 µL99.61100.02
50.0 µL49.2850.01
10.0 µL9.6210.00
As-left deviation+0.02%
−0.6%Nominal+0.6%

Illustrative · 21 CFR Part 11 records

Pipette Instruments We Service

Every major air-displacement manufacturer, plus the balances and dispensers around them.

See what we service
  • Eppendorf
  • Gilson
  • Rainin
  • Thermo Fisher
  • Sartorius
  • Hamilton
  • BRAND
  • VWR
  • Oxford
  • Socorex
  • Nichiryo
  • Labnet
  • Integra
  • Corning
  • Mettler Toledo

Don’t see yours? Send the list — coverage is confirmed before we quote.

One calibration partner

Whatever your laboratory needs calibrated, we can be the one provider.

Most laboratories end up with one vendor for pipettes, another for balances, and a third for whatever is left over. Each one brings its own schedule, its own paperwork and its own invoice.

One point of contact
Named technical contacts who know your instrument list, your interval and your quality system — not a ticket queue that starts from scratch every visit.
One asset register
Every instrument on one due-date schedule, reconciled against your own register rather than kept as a second list that quietly drifts out of date.
One record format
The same certificate, the same as-found and as-left data, and the same 21 CFR Part 11 compliant records across every instrument category we touch.

What we cover

Six instrument categories, one provider.

  • Single-Channel Pipettes
  • Multi-Channel Pipettes
  • Electronic & Repeating Pipettes
  • Bottle-Top Dispensers & Burettes
  • Analytical & Precision Balances
  • Automated Liquid Handlers

How it works

What happens when you call us.

Four steps, no surprises. You know the cost and the schedule before anything is committed.

  1. Send your instrument list

    Counts, manufacturers and channel configurations — or a photo of the drawer. We work from whatever you already have.

  2. Get a written quote

    A technician reviews the list, recommends a plan tier per asset, and sends an itemized quote within one business day.

  3. Pick your date

    Choose an on-site window that fits your workflow. Your instruments never leave the building.

  4. Service and documentation

    Calibration runs to your plan tier, and certificates with as-found and as-left data follow on the same cycle.

0+
Instruments calibrated

Since inception

0
Instruments per service day

Per technician on site

0.0%
On-time completion

Trailing twelve months

0states
On-site coverage

Mid-Atlantic service region

Pipette service plans

Three tiers. One decision: how much proof do you need?

Every plan starts with a complete preventive maintenance service. What separates them is the depth of the measurement record you get back.

Silver

Functional verification

Preventive Maintenance Calibration

Keep instruments healthy and working correctly.

  • Complete preventive maintenance (PM) inspection
  • Cleaning and lubrication as needed
  • Seal replacement when required
  • Functional testing

Recommended for

Non-GLP research laboratories, teaching laboratories, and routine academic use.

See Silver details
Most chosen

Gold

8 measurements

Enhanced Performance Calibration

Measured proof that the instrument performs.

  • Complete preventive maintenance service
  • Calibration at 4 high-volume samples
  • Calibration at 4 low-volume samples
  • Multi-channel: 3 high-volume samples per channel
  • Multi-channel: 3 low-volume samples per channel

Recommended for

Laboratories requiring increased confidence in pipette accuracy and precision.

See Gold details

Platinum

15 measurements

Comprehensive Calibration Service

Our most rigorous protocol, built for audit.

  • Complete preventive maintenance service
  • Single-channel: 5 samples each at low, mid, and high volume
  • Multi-channel: 5 samples each at low, mid, and high volume
  • Detailed calibration report
  • Measurement uncertainty (if requested)

Recommended for

GLP/GMP laboratories, pharmaceutical, biotechnology, clinical, and quality-controlled environments.

See Platinum details

Standards & compliance

The paperwork is half the deliverable.

A calibration you cannot defend is a calibration you did not really buy. Every protocol we run is built against the standards your auditor already knows.

A vernier caliper measuring a component, a traceable dimensional standard

Traceability is a chain — every link of ours is documented.

All calibrations are performed in accordance with ISO/IEC 17025, ISO 8655-1, and ISO 8655-2. Our calibration software is 21 CFR Part 11 compliant.

ISO/IEC 17025Testing and calibration laboratory competence
The general requirements for the competence, impartiality, and consistent operation of calibration laboratories. It governs how we control methods, equipment, traceability, and reporting.
ISO 8655-1Piston-operated volumetric apparatus — terminology and requirements
Defines the terminology, general requirements, and maximum permissible errors for piston-operated volumetric apparatus, including the accuracy and precision limits a pipette must meet.
ISO 8655-2Piston-operated pipettes
The specific requirements and test methods for piston-operated pipettes — the protocol that determines how many measurements are taken, at which volumes, and under what conditions.
21 CFR Part 11Electronic records and electronic signatures
Our calibration software is 21 CFR Part 11 compliant, so the electronic records and signatures behind your certificates hold up in a regulated environment.
A working clinical laboratory with technicians at multiple analyser stations

Measurement environment

Temperature
21.4 °C
Pressure
1013 hPa
Humidity
48 % RH

Captured at point of test

Why Gateway Scientific

Anyone can put a pipette on a balance.

The difference is what gets measured, what gets recorded, and what happens when a result comes back wrong.

As-found data, always
We measure before we adjust and report both. Without an as-found result you cannot scope an impact assessment, and an auditor will ask for one the moment an instrument fails.
Metrologists, not parts-swappers
Our technicians understand Z-factor correction, evaporation loss at low volume, and why a pipette can be accurate and imprecise at the same time. That shows up in what they catch.
Schedules we actually keep
Calibration is a due date, and a missed one is a finding. We commit to windows we can hold and tell you early — not late — if something moves.
One team, on your account
You get named technical contacts who know your instrument list, your interval, and your quality system. No ticket queue, no re-explaining your program every visit.

Who we serve

Different labs, different stakes.

A teaching lab and a GMP release lab both need working pipettes. They do not need the same record. We scope the program to the consequence of an error in your work.

Pharmaceutical & Biotech
GMP-controlled environments where the calibration record is part of the batch story. Platinum protocols, measurement uncertainty on request, and documentation built for inspection.
Clinical & Diagnostic
CLIA and CAP-inspected laboratories where volumetric error moves a patient result. Fast turnaround, complete as-found data, and interval discipline.
Academic & Research
Core facilities and teaching labs with large, mixed, heavily used instrument pools. Silver and Gold plans keep hundreds of pipettes healthy on a predictable budget.
Environmental & Water
NELAP and state-certified laboratories where volumetric traceability is a standing audit question and the schedule cannot slip.
Food, Beverage & Cannabis
Potency, contaminant, and safety testing labs under state and third-party accreditation, where method accuracy starts at the pipette.
Industrial & Materials QC
Process and quality-control laboratories that need instruments verified and back on the bench without disrupting a production schedule.

What laboratories say

Trusted where the record has to hold up.

Quality managers, lab directors, and core facility staff across the Delaware Valley and beyond.

“The as-found data is what sold us. Our previous vendor adjusted first and reported second, which left us with nothing to scope an impact assessment against. That does not happen anymore.”

QMQA ManagerPharmaceutical manufacturer, Southern New Jersey

“Two hundred and forty pipettes across four buildings, done on-site in two days, with the asset register reconciled before they left. Our instruments never left our custody.”

LOLab Operations DirectorAcademic research institution, Philadelphia

“We had an out-of-tolerance finding two weeks before an inspection. They were on-site the next morning with documentation we could attach to the CAPA the same day.”

CLClinical Lab SupervisorReference laboratory, Delaware Valley

“Having one provider on one interval is the reason our satellite sites are finally aligned with the main lab. One schedule, one certificate format, one person to call.”

QSQuality Systems LeadEnvironmental testing network, Mid-Atlantic

Frequently asked

Questions we get every week.

Intervals, standards, turnaround, and what actually happens when an instrument fails.

Still have a question?

Talk to a metrology technician, not a call centre. We’ll tell you straight whether we can help.

Get started

Tell us what's on your bench.

Send an instrument list — or a photo of the drawer. We'll come back with a written quote, a recommended plan tier, and a schedule that fits your workflow.

No obligation · Written quote · Monday – Friday, 8:00 AM – 5:00 PM ET